what is phase to phase voltage? what is line to line voltage
Answer Posted / manjunatha bk
Three phases can be connected either in star (Y) or as
Delta (Δ). In star connection the line and phase currents
are one and the same. But the line to line voltage is
square root of 3 times the voltage between a line
(or phase) and the neutral.In domestic connections a
wire from the neutral and any one of the phases are
brought in.
Therefore, in Delta connection V (Phase) = V (Line) = 240
in INDIA
In Star connection V (Line) = Sqaure root 3 of V(Phase) =
415 in INDIA
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
Hello seniors m an engineering student in 3rd yr..i want to know what are the software course in electrical field?i wanted to do certification course but i dont know much about the course?..Regards
What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation
In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.
Efficient electrical earthing in hard rock area
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
size of condotory fron voltage level
WHAT IS VCB SAFETY
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
how can get electrical "c" licence.i am complited in DEEE.PASSING YEAR OF 1993.WORKING IN PVT COCERN LT LINE.PLEASE ADVISE ME .CELL NO 9994786021
If not into production, how far did you follow the design and why did not you see it into production?
what is the difference between unarmoured & Flexible cable? How to identified?
PLZ SEND ME SOME UNIQUE PROJECT OF ELECTRICAL ENG (B.TECH)
Whether IP65 enclosure box blocks ventilation if driver for LED have to enclosed inside IP65 box
rajha power sector details
how to know the diffrential relay setting of 06mva step- down (delta-star)transformer?