Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

among the strectcher, header, english and flemish bond which
has greater strength? where these bonds are preferred?????

Answer Posted / vigneshwaran s

English bond is, upon the whole, to be preferred to Flemish bond for strength, as it contains a larger proportion of headers. The only advantage claimed for Flemish bond is its appearance, which is preferred by many, and has led to its use in brick buildings of a superior class.

In 9-inch walls a better face can be shown on both sides by Flemish than by English bond, as the unequal length of headers causes a rough face when there are many of them.

In walls of 1 1/2 brick in thickness the strength is not so much impaired by using Flemish bond, as it is in thicker walls.

Regards,

S.Vigneshwaran selvaji.

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the code used for residental building?

2539


How to calculate the quantity of cement mortar 2" for mosaic tile fixing 12"x12"?

1746


what is shuttering co efficient?

1908


Explain the term 'Gross unit rate' and identify the items that may be included in the gross unit rate.

11616


Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No.       Loading        Axial force      Moment     Shear 1               DL+LL          1950              600            20 2           Seismic load       250              4800          700

1990


How to calculate cement, water, fly ash amount for 1 cum if the w/c ratio is 0.4 and fly ash to cement ratio is 1:9

2072


to minimize budget cost of building , what can i do

2263


Slump Values for works?

2219


Design a rectangular channel.

2918


strength vs shape factor

2559


What is Gsb tollens ?

2005


what is work of planning deptt. in any construction compny (in road project)

2454


what is the hanekom repairing material after concreting work

2418


I measured pcc work as 15.34 m cube , the ratio is 1:5:10 ,want to know the cement, sand and metal used for pcc measured as 15.34 m cube at this ratio.

2569


Before casting a basement roof slab which is connected with retaining wall surcharge load (i.e. sand or earth filling) outside the retaining wall is prohibited because of––

2415