Answer Posted / amit rajak
power factor is the cosine angle between voltage and current
which balances both these electrical quantities.It is
ideally considered as 0.8 for electrical equipments for its
maximum efficiency.if it is not properly regulated than
there may be rise of any one of the above parameters which
will definitely effect the efficiency
it can be properly regulated by using capacitors in
domestic installation systems
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?
What are the function of different components of servo motor?
WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?
In Plumbing services What are accessories we consider for a bathroom?
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
what is difference between earthingpits,earthing grid & earthing mess?
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
give me applications of sequence bridges . (used in 3 phase un balanced systems)
Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?
What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.
why we r not earthed Control cable of C.T. terminals
What are the symptoms of a bad PG card of a drive (inverter) esp. of Yaskawa Ac Drives (inverters) G7 ?
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
What is the maximum operating temperature for a thermoplastic insulated cable?