how the diesel generator maintain the rpm when the generator
loaded varies from 10% to 70% immediately?
Answer Posted / amit2009786
By using of speed regulator
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
Why the frequency of ac in india is 50 hz but in some other countries it is 60 hz.
Hi, My plant daily consumption is calculated as 3.8MWH but my supplier has sanctioned an power of 2.6MW per day. how can i equal or distinguish this two factors
Why single phase induction motors are not self starting ?
In which working principal temperature transmitter work.explain in detailed.
write down the formula of cable size in RM if current is 50Amp.
Define maximum demand?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
Zone of protection and tripping scheme of arc protection relay.
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.
The power supplied to a 33microF capacitor from a 120V, 60Hz source will be
What is expention fastener (Fan)