What are the disadvantages of LT AVR over HT AVR?
Answer Posted / chintu
High ratings switches and higher size cables are required for LT operated Capacitors.
Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?
A cotter joint is generally used to transmit
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
Why transformer used in UPS??
Under wat condition statcom operates as an inductor for the transmission line?
What is the de rating factor of cable? What is the importance of the de rating factor in cable select
What are the factor to be consider for CT selection in 132kV substation?
role of europe union in UK safety legistlation (electrical safety)
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
tell me about eletrical contractor
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is the transiant condition in alternator? and how it can be prevanted?
Why do we use copper cable for HT Supply and why not Aluminium?
if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value
How to justify this statement ??? "Capacitors in series provide less capacitance but higher voltage breakdown rating for the combination"