I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN
POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL.
1-IS BETTER WE USE CABLE?
2-IS BETTER WE USE BUS DUCT?
my transformer rate power is 2500KVA

Answer Posted / mohamed

BETTER WE USE BUS DUCT BECAUSE :1-LOW VOLTAGE REACH TO 0
2- BUS DUCT WE HAVE BUS BAR WHICH CAN PROVIDED MORE CAURRENT
3-MORE FLEXIBILTITY

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will be the effect if I use inverter as UPS mood?

1755


CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)

1426


How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

1597


Can u explain : what is supply for train (whether a,c or d.c ).I know that supply is 25000v a.c .But there is rumour that supply is D.C. And also explain how lights and fans inside the trains are working ,and what type of motors are used in trains whether D.C motors or induction motors .If d.c motor, how it gets supply.If traction motors are used then what are traction motors and its functions and how it differs from other motors and also explain about locomotive . y d.c series motor in train.train wheels r driven by D.C shunt motor ,at what voltage,and at what speed. please reply..............

1384


please tell me when we start motor without load in star or delta connection whose current above condition,pl write formula

1797






what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1106


What do you mean by cogeneration? What its working principle?

2771


how to find three phase complex power in per unit and MVA?

1654


SUTIABLE FOR ohm's law super conductor

1531


Can any body tell me the different types of LT cables & their application.

1635


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1673


What is the method to solve circuit using source transformation?

662


how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me

1469


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2142


can anyone explain the star-delta motor control wiring ,which wire go where and how they operate?

957