CAN WE CALIBRATE LEVEL TRANSMITTER USING HART
COMMUNICATOR WHEN WATER LEVEL IS PRESENT IN THE BOILER
SHELL?
Answer Posted / deepan
HART MEANS ITS NOT A CALIBRATOR.ITS A COMMUNICATION DEVICE USED ONLY IN SMART TX.
FIRST CONFORM IT GIVES ERROR READING.
IF LEVEL TX IN DRUM GIVE SOME EROTIC READING WE CAN JUST CHECK WHETHER THE TX RANGE & CONFIGURATION.SENSOR TRIM.
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...
What are different types of orifice plates? State their uses.
why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?
sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com
Which language of programing is popular? how can i learn it ?
What is mean by analytical instrumentation?
Why flow/pressure transmitter before control valve?
If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
defination of radial vibration?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Explain the use of hair spring in the pressure gauge.
There are many type of control cable like pair,core,tried, What are defination each one
Explain about the leakage class of the control valves
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies
any questions on motor and energy conversions machines?