Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is purpose of three way manifold valve using for dp
transmitter

Answer Posted / surendar

1) to isolate LP,HP.and check the zero calibration
2)For flashing the impales lines manifold should be close

Is This Answer Correct ?    16 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system

1483


Draw a simple circuit for a well head control panel used to protect the well against fire, leak, blockage, ESD, & controls the operation of one downhole & one surface safety valve. Explain the operation and controls

1572


please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com

1617


what is the reason while warning lamp is on while the engine is cranking?

2062


How to Calibrate Temperature Switch in field

1248


what is cems analyzer explain with principle and drawing ?

2295


How to calibration coriolis flow meter?

1757


need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate

1268


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1414


kindly sent some demo question and answer

1999


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1927


Explain working principle of lvdt?

1037


what is the procedure of O2 sensor(ABB) calibration?

2135


what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1928


How it the difference between force balance system and dispalacement balance system?

2048