In 11kv transmission line whats the maximum power can be drawn?
Answer Posted / gunasekhar
its based on size of the conductor
| Is This Answer Correct ? | 12 Yes | 7 No |
Post New Answer View All Answers
compare between starting charactristics of synchronous motor with those of 3Q Squirrel cage induction motor
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the difference between rectifier and converter and commudator?
how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm
what is sevice settings for mccb?How can be it setted?
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
How can two 3 phase transformers of same KVA and Voltage be connected in parallel?
HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS
hey guys i scored 910 on GRE and 67 on TOEFL respectively.I have an aggregate of about 74%in my B tech.For which colleges should i apply for an MS program in electrical engineering.I am looking for colleges in NJ,SC,NC,GEORGIA, NY. Please reply with a good response.....
why use phase displacement in transformer.and effect of phase displacement on transformer
Write masons gain formula.
How do i right a ladder diagram that has 1 actuator that performs a full stroke followed by a half stroke
Transmission through a short line depends on
I WANT BHEL PREVIOUS QUESTION