If the Power Factor of generator is 0.85...What does this
mean and Can the motors connected to this generator operate
at PF more than 0.85 ?

Answer Posted / eeaadil

Yes motor certainly can operate at better PF than the Gen.
Set as PF is the motor's very own property.
PF of a Generator only specifies about the generator's own
conditions and specs.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.

1915


how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps

734


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

2980


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

1639


What is mean 2XWY

1990






hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com

1640


Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

627


whether fibre optic cable in high voltage earth conductor is used for protection circuits

1176


hi frds, i m electrical engineer.can i get cdr for electrical engineer if u have then send me on my mail id its jayesh_ee88@yahoo.com.please help me frds

1621


WHAT IS THE FAULT WHEN 100HP TURBINE MOTOR TRIPS, LIST THE FAULTS AND ITS TRABULESHOOTING TIPS.. MY AUTO TARNSFORMER STARTER TRIPS

1629


How can we design a HVAC Plant room which includes AHU,FCU,Chillers,Cooling towers, Pumps etc & how will they work? any Drawing if possible?

1879


how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?

2161


what are the sample questions asking to the test cunducting for electrical superwising lisence test?

1666


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2029


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2239