Answer Posted / krajeshkumar1989
reason
1.due to insulation problem..
2.we also change the 50hz to some other hz but we can change the every equipments and power station which are operating at 50hz that becomes extremely very heavy loss (money) for INDIA to change the system frequency.
3. we can also use the frequency from 40 hz to 65hz..
| Is This Answer Correct ? | 0 Yes | 8 No |
Post New Answer View All Answers
What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??
What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)
How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?
What is the previous name of Cox's Bazar
How many types of oil using in H/T & L/T Oil Circuit Breakers. need Explenation ?
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
What current position are you holding in your current company?
Why do we require transformer with less specific weight if supply frequency is increased?
I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.
IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.
What are the types of feedback oscillators?
A jet of fluid strikes a plate What was the force required to counter it?
Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)