Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In lcms analysis some times we get sodium and potassium
adducts. if the compound is havine sodium ions how can we
confirm wether sodium is from sample or it is a adduct?

Answer Posted / spgoswami

If the precursor is sodium ion then intense peak will be of
sodium only rather than the same adduct so we can conclude
by observing lc-ms /TIC chromtgram
Regards

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please explain about aluminium hydroxide assay

1132


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4073


in hplc chromatogram started from left to right and in uv spectrum started from left to right

952


if you given one product then which tests you will perform?

707


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

734


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3667


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

2015


how you determine moist.of NaOH sol or NaOH flacks

2222


can i use hplc detector to uplc and why?

2291


How you develop a method in HPLC?

2616


why salisylic acid not using now days for disdolution calibration?

772


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1979


Loss of linearity in tkn analysis, possible reasons?

1317


mahagenco syllabus for the post of chemist

6476


how decide the clining method and cleaning method validation require for this perticular products?

755