how to synchronize 4 nos. of diesel generator sets of
different capacity (kva)?
Answer Posted / chat lang
yes im agree all your answer because we experience this
kind of problem we use 3nos of 500 and 1nos 1150kva this is
synchonized connection, then the 1150kva genset is shutdown
and he dont want to accept load sharing yes he start for
1hr but then shutdown he dont want to have load sharing in
other genset and on the ((DSE scada module)) telling or
indicating is no communication on main unit, then we
disconnect that ((1150kva genset. the spec of genset is
same like the 3nos 500kva pf 0.8 rpm 1500 HZ 50)) so what
was the posible cause of this problem,
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test
What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.
what is the difference between an alternator and a synchronous motor
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
do any one help me to get "C" license,, i have doubts ,,, if mediators ter pls call me,, my no is 8056640042
hi Is there any possibilities to find out the rotation of a shaft or something else by using electromagnectic waves or by IR rays.If s then can v change the dir., of rotation of the same by remotely?& how? plz dn't any1 say "NO r CAN'T"
Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????
What are the advantages of instrument transformer?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
What is Plank's Law?
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
what is the difference between droop mode and ischnorous mode in thermal powerplant?
what does mean of RCT and STR in diffrential CT?
Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.
As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.