in a transmission line if the load is suddenly increased in
the receiving end of the system the phase shift will ?

Answer Posted / vijay balu raskar

As power flows along a transmission line, there is an electrical phase shift, which increases with distance and with power flow. As this phase shift increases, the system in
which the line is embedded can become increasingly unstable during electrical disturbances.

Simply, load suddenly increases phase shift will increases.

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do I calculate/select Droop CT ratio for various capacity of generators?

3091


What is force on a conductor in a magnetic field ?

628


What is quadrantal symmetry?

1122


What are the types of windings according to the construction?

615


list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.

1564






Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job

1653


how the speed of the gets motor regulated. does it draw the same current on the all speed level.

1465


Explain about Dubai electrical sysaem? Explain about Dubai drinking water system? Explain about Dubai Burj tallest building Electrical,Water.etc.. maintenance system?

1670


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1665


upto how many load can v connect to stabilizer which is used for tv

1741


Tell me in detail about c.t. And p.t. ?

733


what is the importance of earthing system on the generators big capacity and small?

1323


What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?

1759


what is the earth current,reverse power,electrical trip generator short circuit,low voltage, high voltage please discribe me

1651


Is it possible to connect a safety device in to parallel?

1568