can motors working at parallel operation like D.G set and
transformers? It means asking about two motors coupled with
same load???

Answer Posted / raovasuki17

Yes., Motor can work in Tandem for the same load. Some
times when the load is too much we can use two motors with
geared coupling ( Direct) or indirectly coupled through
wire or felt or sprocket and we have to use load sharing
technology ( Available in Electronic drives )

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

1703


are there rmu for 3 transformer?

1428


why the field winding in dc motor is not short circuited eventhough dc supply is applied across the winding

1410


concept of busbar and load dispatching..?

1931


An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.

7022






what are the main faults that occur in stabilizers? How they corrected and resolved ? Types of stabilizers ?

1588


what is the value of combined earthing in general electrical circiut?

1461


Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?

1282


Define what is the function of anti-pumping in circuit breaker?

700


What are the transformer losses?

680


Dear all, how we select the cable size according  to current with or without including different correction factor , is there any direct method for sizing of cable... 

1708


What are the different power system losses and how can it be eliminated?

1574


our factory is going under construction mean time transformer 1000 kva 2 nos &load break swithch 12 kv & 4 nos 750 kva 2 nos & 380 kva 2 nos generator to be errcted.how to arrange earth pits &how to earth connect & neutral pit how to calculate in earth bit size.

1663


along with technical test papers

1141


why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%

1487