Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why buchholz relay installed in inclined position

Answer Posted / alok singh

Buchholz relay is installed in inclined position because of its function as it is used for internal fault protection inside the transformer as in case of over heating and loading of transformer oil temperature also increases hence oil expands inside the body of transformer so that excessive oil expands during heating or time of fault enters in buchholz relays body and after a particular level relays coil get trips and gives an alarm to the operator regarding the fault.

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the minimum IR value of HT/ LT cable? Pls post separetely!!!!!

2432


Why PS class CT is always preferred for Differential protection?

1586


What is block diagram?

1087


how to find number of run cable laying[LT side] for transformer & alternator secondary side? [above condition for getting output power transformer to main panel side] give the example.

2068


what is resver in electrical enginnering with answer

1709


if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?

2020


How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1968


my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking

1331


Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

1968


I completed my BE EEE degree 2006 .... which license should i apply .... ?????

1691


Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.

1750


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2880


How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.

2013


What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?

1109


how to calculate transformer load?

2469