Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diffrence between mmwc and kg/cm2 for pressure
measurment when we are using mmwc and when kg/cm2 and why?????
?? what is the reason

Answer Posted / chirag darji

both r units of pressure itself..but when the system is in
vacuum then the pressure measured in mmwc and the positive
pressure measured by kg/cm2.so for low pressure mmwc used
and for high pressure kg/cm2 is used..

Is This Answer Correct ?    22 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calibrate capillary type level transmitter

1718


what is the usage of QDV & VOLUME BOOSTER

2234


what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail

2257


Define cryogenic?

1084


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2139


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2632


can we copy the software from a transmitter using hht(hart 275) ?

2016


what is intrinscily safe system and where we use?

2435


it is possible to check the fail safe condition in pressure transmitter. if possible how?

1346


we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?

2521


send me HPCL paper

10020


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2442


How will you test a transistor with a multimeter?

1043


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

2153


How we calculate orifice plat size???

1468