What is the procedure for investigation of an OOS (Out of
specification) results?

Answer Posted / ramya

when oos arises inform to the supervisor and discuss the analyst procedure whether they followed wrong or right.if right then repeat the analysis by different analysts.then also result is same means inform to manager and QA DEPT.Get approval from QA and fill the form with obtained results.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Which parameter require to do for analytical method equivalency?

326


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

293


What should be the level/ Percentage of Arsenic in Arsenic free zinc.

1764


In rs method development when we are going area normalization method to dilute standard method?

948


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1457






How we can identify process related and degradation impurity in single method with short period?

338


WHAT IS THE USE OF STARTER ?????????

1911


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

2961


sop of a uv visible spectrophotometer double beam elico model

5357


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

361


pharma industries oriented

1691


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2214


what are risk assement in the analytical qbd?

289


How can I develope method of dissolution by HPLC OR UV

1893


is it nessesary to do solution stability for 7 days?

318