Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

sir,
why alternator output is connected to delta side in to
generating transformer? any reasion?

Answer Posted / laxmikanta sasmal

COZ ALTERNATOR ARE GENERALLY STAR CONNECTED WHEREAS THREE LEADS ARE SHORTED AND OTHER THREE LEADS ARE OUT,THEN CONNECTED TO DELTA/DELTA OR DELTA/STAR CONNECTED TRANSFORMER'S DELTA END.DELTA CONNECTION WINDING IS MANDATORY AT ALTERNATOR OUTPUT SIDE.BECOZ IN SAME VOLTAGE LEVEL TWO STAR POINT IS NOT ALLOWED.IT WILL CAUSE OF HUGE AMOUNT CIRCULATING CURRENT FLOWING IN UNINTENDED PATH AT THE TIME OF FAULT/UNBALANCE AND MALFUNCTIONING OF PROTECTION RELAYS

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

write a c++ code that receives an integer number and display the sum of the number and its revers integer?

1986


Write the force balance equation of ideal dashpot element.

1295


What is Diff btw Fire Alarm & VESDA System???

2338


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1908


can some one clearly explain why -48 volt DC use in telecom site????

1634


Alternator rotor earth fault relay circuit

2018


What is meant by reactance voltage?

1068


how to find Harmonics and types as per the equipemnts

1218


Proviiding the Dedicated N earth and individual Body Earths ,Finally these all looped /Now my Question :- will it not harm in case of Transformer Fault current flows in Dediacted N Earthing to Looped Body Earthing.

2139


what is the use of commutator in dc motor if we supply ac ? commutator is used to convert ac to dc.and it is used to arrange the flux in unidirectional in case of dc supply. if we give ac as supply to dc motor what is the use of commutator?

2036


what are the condition that makes hooter blow?

2373


what is basic difference betmeen normal & flame proof motor??

2104


When we use 3 terminal resistor?

1176


what is the major difference between LIBBP & HIBBP.. which one is most preferable..

2882


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

2218