why cant we use mV instead of mA?
Answer Posted / mohammed
because we cannot lay a cable for more than 50 m to carry mV
signal whereas we can connect current signal cable because it
is less diameter, will not affect by noise and not costly in
addition can be connected for long distances
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
What is Span Error
hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Which products are available in the Mass Systemswitch and System Manager AC range?
How does work A temperature valve or fv control valve in process plz brief me
what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...
What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
What is the principle of capacitance type level transmitter?
centrifugal compressor interlock? Tell me the parameter at which compressor will trip
What is limitation of the ht.of the displacer of a level trol?
can we copy the software from a transmitter using hht(hart 275) ?
DEAR SIR/MADAM MY NAME IS ARKAPROVA BHATTACHARYYA.I AM A FRESHER INSTRUMENTATION ENGINEER.CAN YOU PLEASE SEND SOME QUESTION PAPERS OF GRADUATE ENGINEER TRAINEE EXAM OF DVC(DAMODAR VALLY CORPORATION).MY EMAIL IDs ARE arka_aec@rediffmail.com.