If a 1.5V,3W torch light bulb is connected in series with a
15HP/11.19KW,230V single phase motor and the combination is
connected against a 230V supply and switched on than what
will happen keeping all other parameters as it should be
A)the bulb will glow normally B)the bulb will not glow C)the
bulb will glow with extra brightness D)the bulb will burn
out and if a fuse is connected to the above circuit will
something happen to the fuse and what about the single phase
motor will it be affected?
Please explain with derivation
Answer Posted / s.s.kothavale.
Normaly bulb will draw 2amp current. So you may use it as
2amp fuse in circuit. 15 hp motor will draw huge current
while starting, hence bulb will get fused instantly.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the disadvantages of autotransformer?
Draw the line diagram of diffretial relay connected to transformer?
what is the difference between dry and wet type of 132kV terminations. which one is durable
i am completed my degree(B.E EEE) 2014 anychance to get electrical licence plz help me
HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.
what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips
Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially
how to calculate the earth fault current
In HI POT test what is reason for applying the AC VOLTS and DC VOLTS in different applications what is the nessesity for this ?
WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .
When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number
please give me all the Alarm .Trip ,Safety Relays & Conditions of Diesel-generators mail me on ashokbabunhce@gmail.com
What is installed in PAC that is control the humidity