Whats the difference between three phase and single phase?
Answer Posted / amjith meeras
in three phase system we can use it in two modes one is delta connection and other is star connection,
in delta connection we will get only phase to phase voltage, in india its 415vtg its because of there was no neutral point in delta connection.
but in star connected it has one neutral point and 3phases in R-Y-B sequence so we will get phase to neutral voltage and phase to phase voltage from it.
for ex: the transformer primary was connected with 3phase 3core cable but its secondary side has one neutral and three phase it connected with 4core cable.
all machine other than motor wants neutral for it work.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?
who can measure the size of power cable?
why we are using Load factor?
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
What is the necessary and sufficient condition for stability.
If you have an earth with pilecap then your resistance is really low. why and how?
What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?
what is meant by moulded case circuit breaker ?
ELECTRICAL ENGINEER TEST IN FEWA ANY ONE HAVE KNOWLEDGE ABOUT THIS?????????
How to control motor gearbox speed and friquency? If length of cable and dia given, how to measure the voltage drop?
What is the ratio of true power to apparent power in an ac circuit?
How many types oil using in transformer ? How many letars using in transformer..?
The power supplied to a 50mH inductor from a 120V, 60Hz source will be
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
Salient pole alternator is more stable, why?