Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can i get any detail of interview question asked for
instrumentation,plc,scada ,dcs..............

Answer Posted / prashant sanas

What is the difference between PLC and DCS control system?
PLC is an completely industrial automation system, where as DCS is an computerized control system.
PLC is economicaly low cost, but the DCS costs high.
Also,
DCS stands for Distribute control system
Actually DCS is a network hub which can collect the Required Info from the other PLC's (say 2 or 3 & so on..) and then processed it... to get the full info about the Plant Operations(say current rating Temp. voltage load and Power Factor etc)..
ok

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Do you have reference list?

1838


what about your moleg in pogrees with company

2279


How to calculate P,I&D value in PID controller ?

2141


what is vibration a part of proceess variable? if vibration is a part variables then how we minimize the actual vibration on machine on load,? vision of instrumentation contrl plz ans me IPGDL interview question

1929


what is the calibration procedure for magnetic flow meter @ onsite

1655


what are the use of belew gear in general ??

2003


What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?

1200


How to calibrate H2s Dectector

1619


WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?

2134


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

3185


Differentiate between ultrasonic flowmeter and radar type flow meter

1217


POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?

2292


how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.

2488


Emergency Shutdown Systems/ Plant Shutdown System.

2267


Calibration of controller (pneumatic)

1976