What is Primary and Secondary Injection Test of CT and
Relay.
Answer Posted / roy
primary injuction means we will inject the current in the
primary of the current transformer. and according to the CT
ratio and relay setting the relay will operate.
secondary injuction means we will disconnect the wires from
the secondary side of the CT and inject the current to the
relay directly. the relay will operate according to its
threshold.
| Is This Answer Correct ? | 23 Yes | 5 No |
Post New Answer View All Answers
How shall i select the value of capacitor or inductor in a system?
What is the magnetic field (coil DC ) of Turbo Expander?
How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?
i need the details about bhel exam.how to apply for that.please send to my email-id.thenmozhi2k7@gmail.com
how to discharge 3 phase power factor correction capacitors
Which type of air compressor is used now a days in the market. Keeping in mind of energy efficiency and maintenance points. Relevant documents may also be sent on mentioned email ids.
what is the transmission loss for electrical supply? specifically a large shopping complex where the grid is half KM away, what will the % of transmission loss? is there any transmission loss for captive unit generation for above set? thanks
What is oscillator circuit?
what is meant by motor startup supervision & motor load jam protection ?
What is the suitable transmission voltage?
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
Why we use Electrical energy rather than any other type of energy, mostly? Explain behavior of open secondary CT and short circuited secondary PT in energized condition?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
how the phase convertor changes the no. of phases