Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Procedure the procedure to select CT's & PT's in
66kV and above substation?

Answer Posted / manohar

The above answer is correct , the procedure is same in
selecting 6.6kv also

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1)Explain why the cradle guard is used on railway crossing in overhead line construction?

5008


What is s-domain and its significance?

1132


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

2184


Why the frequency of ac in india is 50 hz but in some other countries it is 60 hz.

2102


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1861


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

1028


Safety of on line ups

1908


how can i find ct ratio of meter by seeing name plate of meter and how it should be used in MF calculation if it shows only-/1???

1675


How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester.

2280


WHAT ARE THE CHARACTERISTICS OF AN VOLTAG AMPLIFIER

1986


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

1953


distribution transformer de-rating formula on over limit iron losses  

2261


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2134


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2626


Wt is the function of reactive power? How it generates & consume though resultant is zero?

1855