Answer Posted / navneet phogat
Three phase induction motors are used wherever the application depends on AC power from the national grid. Because they don't need commutators they are particularly suitable for high power applications.
They are available with power handling capacities ranging from a few Watts to more than 10 MegaWatts.
They are mainly used for heavy industrial applications and for machine tools.
The availability of solid state inverters in recent years means that induction motors can now be run from a DC source. They are now finding use in automotive applications for electric and hybrid electric vehicles. Induction motors are seen as more rugged for these applications than permanent magnet motors which are vulnerable to possible degradation or demagnetization of the magnets due to over-temperature or accidental over-current at power levels over about 5 kW. Nevertheless, the induction motor can be ill-suited for some automotive applications because of the difficulties associated with extracting heat from the rotor, efficiency problems over wide speed and power ranges, and a more expensive manufacturing process due to distributed windings. Permanent magnet and reluctance motors may offer better solutions for these applications.
| Is This Answer Correct ? | 19 Yes | 2 No |
Post New Answer View All Answers
we can run 2phase as 3phase .what will be the differnce with respect to phase angle, power, current between the two modes
What information we need to prepare relay coordination chart
what is mppt (maximum power point tracking ) and how they used in solar power generation ??? what are the main components used in mppt?????
how to decide the capacity of accl
why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%
Pls Breifly explain about UPS (Inverter,Reserve,Rectifier,Float voltage,Boost voltage).
Differentiate between induced emf and self inductance?
what is sevice settings for mccb?How can be it setted?
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
Define Electrical Insulation and examples of Solid,Liquid and Gaseous insulating materials?
What is the difference between alternator and generator?
how to increase or decrease speed in DC shunt motor by DC convertor
What do you mean by ratio correction factor of instrument transformer?
What is precision of a measurement?
1hp= how much rpm