Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have connected 04nos. earthings to a transformer through
04nos. earthing pits seperately. 02nos. earthings are
connected to T/F body, and 02nos. earthings are connected to
T/F neutral.T/F capacity is 2000KVA, 11KV/415V. But after
completing of 02 years successful operation ,we are
facing following problems-

1. CT/PT occured blast one time
2. HT cable box occured blast two times
3. One body earthing strip and one neutral earthing strip of
transformer are overlapping at some places. Whenever these
two strips are pressed at overlapped points, they made spark.

What is the reason of spark?

Please explain the reason & rectification of above problems

Answer Posted / siva kumar

because of improper earthing the transformer neutral voltage may raise to abnormal level and may cause failure of CT/PT sets.
The star point you made on secondaries of CT, should be made at the equipement only and connected to earth to avoid transfer potential.
If you have not integrated your earth pits,
connect all the four earth pits with 50X8 GI flat.
now check earth pit resistance is with in limits.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How isolater function when installed inelectrical 440V wiring

2240


what happens if earth of 33kv cable is not connected to earthing pits? please send this query's answer to ngrm.sudha249@gmail.com

2038


if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.

1973


how the aircraft outer body and inner body is separated ?

1068


What is the slip speed?

1091


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2044


How does cost of generation from hydropower plant compare with other sources of electricity?

1057


Explain thin film resistors and wire-wound resistors

1028


what is negative d.c. voltage, why this voltage is used in base transciever station.

2161


What is Annunciation?

2035


what are the types of electromagnetic forces developed in practical transformer?

2632


what is meant by directional earth fault and non directional earth fault? describe both.

1901


Draw a SLD of HT distribution EB grid up to users Transformer?

6207


can anybody send the rrb chennai &rrb bopal question papers of 2006&2007.My exam is on 12 oct 2008.Its urgent

2051


how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?

2172