What is WLD System????

Answer Posted / sabir contractor

it is water leak detection system.basically it is used in
data center/ server room. it is many types1. wire based and
snesor based. whenever water touch to the cable then alarm
will generate.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What if the difference beween internal and exrteranal LBB?

1218


How to calculate ant test the burden of Current transformer

1967


what is settable hystersis protection? If any body knows plz kindly post the answer..

1562


What is relation between mu(nought) and epsilon(nought)?

884


Explain what are inter-poles and why they are required in a dc machine.

641






how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

1748


How to check the thermocouple is correctly connected to cable for K type? (i,e positive pole is connected to non magnetic conductor and negative pole is connected to magnetic conductor)

1260


Is there possible to Test Transformer for Overfluxing Capability. Or is there any firm who does Overfluxing Test on Transformer?

2647


what is difference between cpp electrical system and refinery electrical system

1752


what is the solution for meger test failed the MV cable?

3542


How to decide and select the different earthing wire size for the different types of earthing

1816


Why armature rheostat is kept in maximum position?

642


can u give me a brief idea about power line carrier communication ??

1499


what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:

1535


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1586