What core magnetic balance test of transformer?
How to do this test in a three phase Star delta (star-LV,
Delta-HV) transformer?
How to measure and where to measure?
thanks and regards
Austin
Answer Posted / joshi nikhilesh
appliade volage IN H.V SIDE APPLIADE VOLTAGE IN L.V SIDE
RY rn
measured voltage measured voltage
RY,YB,BR rn,yn,bn rn,yn,bn
and reapit this all step appliade YB,BR yn,bn and
measured abouve step
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
what happen if field of dc shunt motor opens? what is function of putting res. in parallel to one phase of 3 phase IM? the power supplied by 5A source in circuit is given by------Watt.
what is the working process of over & under voltage relay.
How to calculate the Harmonics losses in terms of cost/unit.
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
in parallel operation of power transformer why the distance between power transformer and capacitor bank feeder is necessary to know
Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.
Why the field rheostat is adjusted such that the voltmeter reads 380V
What is the meaning of HT Trivector Meter ?
how does ELR works? explain
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
what is the difference between skin effect
what are problems caused by the pdu in rack server
What is the formuala to calculate the rating of motor protection circuit breaker