Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What happens when the power factor is leading and its
disadvantages.

Answer Posted / a.p.nanjappa

THIS IS CASE USEFUL FOR UTILITY GRID MANAGEMENT.
GENERALLY EACH POWER GENERATION EQUIPMENT IS MANUFACTURED
WITH say 162MW is designed to operate on 80MVAR 0.8PF
LEADING and 30MVAR 0.8-0.9PF lEADING. THIS IS THE PROPERTY
OF gENERATOR CHARACTERISTICS.
wHEN GENERATOR IS CONNECTED (SYNCHRONIZED), WITH GRID,
THEN ,GRID DETECTS THE lOAD. AS DEMAND INCREASES THE POWER
FACTOR CHANGES FOR LAGGING TO lEADING. THE MVAR EFFECT IS
MORE IN PEAK LOADS,BASE ,..
THE EFFECT OF POWER FACTOR ON GENERATOR IS THE ROOTOR GETS
HEATED DUE TO REACTION OF ELECTROMAGNETIC FLUX DEVELOPED
BETWEEN STATOR AND ROTORS FIELD.
the stability of the grid is to be increased by MVAR
compensator or capacitor banks according grid compensation.
as Utility is another organization ,they take advantages of
capacity of genarator.as a result , generator is subjected
overheating, if operated still, the generator is pulled out
of synchronism and trips.disadvantage is shoter life due to
rotor heating and expensive repair,prolonged unscheduled
outage,revenue loss.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why ct ,cvt should be stored in a vertical position?

2627


how is the cable tray designed & how its total length is calculated for an Industrial plant Say for Ex. (500KW Motor Load)

1889


What are the causes of unbalanced current on 34.5kv feeder Ia=0.05,Ib= 0.25, Ic=0.15 and In=0.27 prior to tripping current are balance?

1734


What is Antipumping Function & If we have C.T how we find the Ratio ?

2022


if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current

1695


What is class ab operation?

1046


What is the emf equation of a transformer?

1248


1hp= how much rpm

2067


What is the basic principle of operation of alternators/dc generators?

1099


On Which Pressure PRV is operated.

1718


How to calculate the Harmonics losses in terms of cost/unit.

2022


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1916


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2029


What are the main parts of central chiller plant? Explain the function of each stage.

4797


Explain Circuit Breaker Trip Characteristics in detail.

2130