how to replace 8mm bar with 10mm bar if the the 8mm bar is not available..???
Answer Posted / subhasis1991
You can think this in other way...
To use 10mm dia bars you just need to calculate spacing to be provided.....
When you are to use 8mm bar you would be provided the spacing(S1)..Now the spacing to be provided for a design is dependent on bar area(which is proportional to bar dia^2)...For greater bar area spacing would be less and vice versa ,so spacing is pretty much inversely proportional to the area of bar...Now to get 10mm bar spacing you just need to calculate :S1*(10^2/8^2) and you are done..
| Is This Answer Correct ? | 20 Yes | 10 No |