if we put any thermocouple on a table in a room without any
connection,what temperature should it show.

Answer Posted / deepak

as we know working principle of thermocouple , mv generation
is function of temprature difference between hot and cold
junctions, in above case we are keeping thermocouple on
table in room .means both junctions at same temprature hence
it should be shown zero temprature.for example,
if room have 30 degree temp.then hot -cold= actual temp
30- 30 = 0

Is This Answer Correct ?    33 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

There are many type of control cable like pair,core,tried, What are defination each one

1818


what are procedure of sox-nox calibration

2534


what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .

4493


sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.

2091


How many interlocks at turbine side?

1519






Calibration procedure for electro magnetic flow meter

1637


where proximity sensor installed on tank in loading arm application

1892


what is difference between fork type and capacitance type level switch. where it is using

2021


HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with

1724


i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?

1880


IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?

2056


can u briefly explain aboutan aryton shunt multirange DC ammeter?

2400


In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?

1501


Why not come out analog output in ABB EL3020 when display show correct value

1551


sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com

1894