Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Synchrounous motor is three phase motor,but its not self
starting .why?

Answer Posted / santosh kumar sharma

synchronous motors are not self-starting motors. This property is due to the inertia of the rotor. When the power supply is switched on, the armature winding and field windings are excited. Instantaneously, the armature winding creates a rotating magnetic field, which revolves at the designated motor speed. The rotor, due to inertia, will not follow the revolving magnetic field, but instead acts as a synchronous generator (alternator) and creates a very large counter-current that opposes the rotation

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2219


When we need up only in o/p 440v, so why we use directly in 11kva in input?

1688


why ht motors are star connected?

1883


In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?

1989


how to get electrical supervisor competency certificate in gujarat. i did 3 year diploma in electrical

2577


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

2032


why we use condenser in the thermal power plant, althrough the same vapour will be again heated

4890


What is the basic principle of welding process?

2152


-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

2105


which VFD is better ( LT or HT)

2073


how to check ac servo motor

2277


what is the formula to calculate voltage drop/loss on 66KV Transmission Line?

3702


Star Delta Diagram with full description

2396


Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp

3140


The advantages of Magnetic flux leakage technique over Ultrasonic technique for non distructive testing of material.

1990