What is Integral and Derivative control?
Answer Posted / rizwan
In simple u can say
Proportional----how much controller will open or close
Integral---how long it will keep the same controller opening
Derivative----how fast controller will complete its action
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
tell me the field & lab calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter, temperature transmitter, temperature indicator, flow indicator, level indicator, control valve, thermocouple, pressure indicator (digital & analogue),
What is three element drum level control system why its better than single element?
What is the use of each wire in three wire RTD
How many interlocks at turbine? Plz explain briefly
how to turbine speed measurement?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
where proximity sensor installed on tank in loading arm application
What is the purpose of bypass valve across AS valve.
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
is motorized valve closed when power shutoff?