why transformer ratings are in kva

Answer Posted / naveen kumar

Temperature rise depends on losses which in turn depends on voltage and current rating..... so V*I
By the by we don't know the pf of load to express it in KW

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the advantages of using distance protection schemes as opposed to normal overcurrent/ earth fault protection on high voltage feeders.

3171


WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???

2012


If I want to buy a new Xformer for my plant what are the main parameter will I need to check?

1526


Why mostly the HV side of transformer has Delta?

2846


static chagre

1790






which type of cabel

2040


1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai

1513


What are the components of feedback control system?

728


How to select HT/MV cable size ?

2108


my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking

967


how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....

1660


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3477


What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?

1909


how does high earth to neutral voltage affect electronic equipment?

1053


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1798