On liquid service if PT Head is 18 meters. How much pressure
will be exerted on it. If Transmitter is not in service?
Answer Posted / dickie
Depends on the specific gravity of the if it was water s.g=1 10 metres head is equal to 1 barg of pressure so 18 metres would be 1.8 barg or 26.1 psi
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
What are the application of bernoulli’s theorem?
Please asked me How calculate DCS controller memory.
all types instrumentation questions want
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
why would you like to join our company
I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
flow transmitter formula?
principle of dead weight tester ?
If we increase only P what will be controller action ?
How to Calibrate Temperature Switch in field
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
Which language of programing is popular? how can i learn it ?
what is the difference between magnetic flow meter and mass flowmeter
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.