when 40 watts and 60 watts bulb is connected in series,
which bulb glows brightly ?
Answer Posted / wareagle
posted by Syed "so calculating resistances,
R60=240*240/60=960ohm,
R40=240*240/40=1440ohm,
Req=(960*1440)/(960+1440)=576ohm,
Total current through the circuit:"
The lights are in series not parallel. You are calculating
the parallel equivalent. of course the 60 watt will be
brighter in parallel. But the question says series.
Try it over in series and the 40 w will be brighter.
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
The height to which the liquid in a tank to be maintained for a certain constant velocity?
what is formula to cal cute earth pit numbers and size of earth strip used in earthing?
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.
What are the types of the glands and difference between single and double compression type of cable Glands.
what are the tests comes under the type test, what tests comes under routine tests.
How we can calculate the life of Lead acid battery
How can we checked Killo Watts of Motor & Alternator?
What are books to be referred for KPTCL exam?
please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com
why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?
PLEASE SEND ME NTPC RELATED INFORMATION LIKE WHICH TOPICS HAV MORE SCOPE,BOOKS TO READ,CUT OFF...PLEASE.mail at thiru.1203@gmail.com
hi if anybody got model questions for cpcl Grade'A' electrical engineer position.send it to my mail please krishkumar22@gmail.com
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
how to determine ct ratio in ht vcb?
how to find three phase complex power in per unit and MVA?