why can't we increase the voltage by increasing the field
voltage in order to get higher voltage.so that we can
eliminate step up transformer
Answer Posted / waqar ahmad
Every machine is designed for specific insulation level
against voltage level. So increasing voltage, insulation
can get puncture & as a result machine will get failure. so
voltage can't be increased from predefined / designed lavel.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the slip speed?
Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?
what is the relative size of single and three phase?
how to calculate the earth fault current
Which standard we are following earthing resistance test
Explain the terms real power, apparent power and reactive power for ac circuits and also the units used.
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
why a tester wont shock while testing the power in house
What are the disadvantages of thermal power plant?
What are safety device in vcb and acb?
A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.
in our all power plant have connected in grid and grid voltage and plant voltage is same, but as per as electrical concept the power will transmit from high potential to low potential but here altough same,then how power transmit from power plant to grid.
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
if flux and load static in dc motor and supply voltage increases 20% then what happened in speed
which fault is severe and why?between lll fault and lllg fault which fault is severe and y?