Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

water is more polar than acetonitrile.but in reverse phase chromatography peaks elute earlier when we increse Acetonitrile.what is the reason.

Answer Posted / muralikrishna

Even though water is a polar sovent the elution strength of
Acetonitrile is more than water.

Is This Answer Correct ?    52 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can give the expiry period and restadardisation of volumetric solution

2602


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3131


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1977


Difference between hlaf and rlaf

2117


Why Ethanol is Used for Standardization of GC Head space?

4233


if rsd failed then what require to do?

847


What is aggregate and fragments in SEC?

2119


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2034


if you have given one product then how you determine the impurity in that?

750


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1874


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2895


Which parameter require to do for analytical method equivalency?

788


What is Band broading effect explain

1889


all types of questions asked at the cipla interview

4689


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2142