Answer Posted / ashish patil
Auxillary relay used to multiply the contact & used at
different function.eg. Buzzuloz relay have only ONE trip
contact By using this contact we operate Auxillary relay &
contacts of this relay used for tripping,indication,SCADA
etc
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What types domain of laplace transforms? What behavior can laplace transform predict how the system work?
What is the function of Governor in Hydro Power Station? What is the Function of Lightning Arrestor Voltage Transformer (LAVT)?
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
What is expention fastener (Fan)
In a carnot engine with an efficiency of 40%, the heat rejected to the sink at 27 C is 60 kJ, then the heat supplied in kJ to the engine by the sources is
what is a pilot wiring and whys that called a pilot wiers
how to calculate the conductor size for certain KV transmission line and distribution line?
what is earthing transformer? draw the winding dia.of earthing transformer.
What happens to a motor if it is connected in Delta connection
what is the main difference between power devices and signal devices
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
What is the permissable nutral current of three phase system as per IS standards?
What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side