A temperature sensor (RTD) connected via a temperature transmitter is adjusted to give an output of 4ma at 60 deg and 20 ma at 600 deg.
This output (4-20ma) from the transmitter is connected to an IGBT-inverter to control a high speed (-12,000 to +12,000 RPM) DC motor.
And in the inverter it is programmed as, for 4ma the motor speed will be -3,000 RPM and for 20ma the motor speed will be +10,000 RPM.
The question is : If the motor speed is +5,500 (RPM), what will be the temperature?
(-sign indicates that the motion is in reverse direction).
Answer Posted / kusito
Temperature = 109.5 deg; output = 7.3 mA9
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
What is frequency factor in massflow meter? When using frequency output?
Which types of quections asked in interview for FORMULATION PLANT (PHARMA)
TECHNICAL/ARTITUDE
Explain working principle of lvdt?
what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...
Differentiate between ultrasonic flowmeter and radar type flow meter
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
How we calculate orifice plat size???
what is metal of piston ring
typical loop drawing of a simple feedback control comprising of one transmitter and one control
What is the cascade control
How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)
principle of dead weight tester ?