what is power factor for any engineering equipment?? what
should be its value?
Answer Posted / raji g
We can simply say that the power factor is how the machine
effectively consume the active power.For example if the
motor runs at 0.8pf it consumes 80% of active power and 20%
of reactive power.
Theoretically speaking the power factor is defined as the
cosine value of angle which between the voltage and current
| Is This Answer Correct ? | 10 Yes | 0 No |
Post New Answer View All Answers
what is the voltage rating of chiller unit sensors
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
What are the two basic types of transformers?
all the technical question with answers pleas send your email id ramar_eee@yahoo.com
can you please send me the technical questions and aptitude questions of honeywell and jindal steel electrical engg. question paper my e-mail ID is(kkesavanraj@gmail.com)
Can anyone explain me about the capacitor calculation
When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?
I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???
Can we use shunt trip coil instead of trip coil with protection relay for protection?
Is there a diode made that works with AC 120 volt 20 amp? If so can it completely stop all current flow in 1 direction at all times?
what is the isolation transformer. what is the isolator?
how to calculate short circuit current for the busbar
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.