Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between LT and HT power supply?

Answer Posted / raghwendra singh

LT supply is in the range of 1100 volts.

HT supply is in the range of 6.6,11,22,33,132KV

Is This Answer Correct ?    42 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc

1848


for 750 kw LT load what will be the ht kva

1657


WHAT IS MEANT BY DERATING OF THYRISTOR?

2967


How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.

1502


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2598


what are the main applications of transistor in non-linear region?

2058


why does the magnetic balance tests at transformer?

1961


What is pole of the system?

1156


what is difference between isolation and ultra isolation transformer?, what is the method of testing ?

4338


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1750


1.why should we connect the measuring instruments in l.v side in short circuit test of a transformer? 2.why the power factor is less in open circuit test of a transformer?

2078


1)Explain why the cradle guard is used on railway crossing in overhead line construction?

5063


How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?

2120


why swinburnes test cannot be performed on series machines?explain

2357


In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.

4260