Answer Posted / ms. stanley
DLI - For Test and Development Regions
- When required to Manipulate your own data not affecting
Live Environment
- Allocates the dataset in the TSO Address Space
- Default Access mode
- JCL requires the definition of the DB Datasets
BMP - For Prod Environment
- Against Live DB
- Multiple User access
- No Dataset specification in the JCL
| Is This Answer Correct ? | 11 Yes | 19 No |
Post New Answer View All Answers
how do you bind the cobol with db2
What do you mean by hierarchical database?
What is ims (db/dc)?
Explain the two ways in which dl/i interface can be invoked?
Explain the processing modes available in ims db?
What is the maximum number of levels allowed in ims db?
how to create a changeman read only audit and update only audit Specifications for the Read only Audit 1) Read HFFD database unqualified. 2) Read FDRT, FDDM, FDAP segments. If FDAP-APP-STS is ‘2’ read the FDAV segment and get the FDAV segment which has FDAV-APV-OPTION as ‘X’ If FDAP-APP-STS is ‘5’ read the HFAC database. Read the ACRT segment qualified based on the key obtained from the FDAP segment from HFFD database. Conditions for writing into output file: a. App Type should be NEWR b. App Status should be 1, 2 & 5. c. Write 50 records per app status. For e.g. first 50 records for App status 1, 2 & 5 each The output file should contain the following fields from the database FDRT-COMP-CTRY-CODE X(03). FDRT-CUST-ID-NUM X(10) FDDM-DEM-SEQ-NUM X(01) FDAP-APP-SEQ X(02) FDAP-JNT-IND X(01) FDAP-APP-STS X(01) FDAV-APV-OPTION X(01) FDAV-APV-DT X(06) FDAV-APV-AMT X(07) ACRT-ACCT-NUM X(06) ACRT-SEG-BUS-TYPE X(02) ACRT-NM1-LAST X(19) ACRT-NM1-SS X(09) ACRT-NM1-1ST X(12) ACRT-NM1-INIT X(01) ACRT-NM1-SFX X(03) ACRT-NM1-TITLE X(02) PSB – DVAN2BMP In case you get a GE for any of the conditions, write to output file along with the details of the database segment which was not found. We need to complete this whole process by tomorrow. Run the audit in DLI mode. 2) Sort the output file created in step 1 on Cust ID, Dem Seq & App Seq. Specifications for the Update Audit 3) Take the output of step 2 as input for an update audit. Details are as follows: Read each record & check the app status. If app status is less than 2 then update the FDAP-NEW- MONEY-ENT to $25000.00 PSB - AUDBMPJ The job would be a BMP job. The test job would be run in IMSE region. Note - The proc (which will be called by the job) and the job should also be present in the change-man package itself. You’ll have a test job in your PDS along with overrides to execute the program in test regions. The job would be a DLI job. The test job would be run in IMSE region. It’ll have the following steps. 1) Delete-define output and error files. 2) Use a copybook for the output layout.
What are the disadvantages of a hierarchical database?
What is the maximum number of segment types allowed for a single database?
What are the two types of fields available in ims db?
What is hierarchical database?
What is bmp mode?
What are the main control blocks available in ims db?
Explain the advantage of dynamic generation of acb?
What is the maximum number of pcbs allowed in a psb?