Answer Posted / remo
At the time of generation there are many type of losses
therefore earlier use to write 10(+/- 1%)kv so thats why we
generally use to write it as 11kv.Since our ancestral make it
a standard of 11kv,33kv,66kv and as the year pass,many
engineers added a new myth of form factor,10% loss of actual
power.....and thus it make us to suffer a lot.
Since there is 230kv and still like 765kv which are not
multiple of 11.
and production in 11kv and 33kv is more ecnomical
| Is This Answer Correct ? | 7 Yes | 3 No |
Post New Answer View All Answers
Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?
how we decide wire gauge for ac or dc coil and what is the basic diff. B/w these two coil?
How can we calculate the KVA rating of a Distribution transformer from its core details?
How to select transmission line type (i.e. 11kv or 33kv) for new established industries
What is the previous name of Cox's Bazar
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
what is the series parallel connection of capacitors? and how can we use these application in three phase motors for controlling torque?
please send me RRB electrical engineer previous year questions for Sr. Section Engineer
what is the significance of cabability curve of alternator
HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION
what is cascade speed control device?and how this device control the speed of motors?
Why front mounted CT polarities are always towards breaker?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
HOW TO CALCULATE HV CABLE SIZING?
should %impedance be high or low in a power transformer? if so why?