Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why induction
motor can not be
operated at
synchronous
speed?? what
would happen if
it is operated
at synchronous
speed??

Answer Posted / dwivedi sandeepdhar

if ind. motor operate at synch. speed than there will be no
rate of change of flux and hence no induced emf hence no
torque.

Is This Answer Correct ?    26 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is size 00, 01, 1 etc., in HRC fuse types?

2302


description with working of all parts of a Diesel generator???????

2391


In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.

1909


Parts of machine and their discription in details with suitable photo

1999


Dear Brother can u tell the proper size selection of cable & the fault level calculation of braker, busbar etc. pls mail me at azeemk30@gmail.com

1873


can i connect the two phases of scott connected transformer,if not why?

1918


in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.

2025


how to select the automotive wire size by mathematical calculation. for xenon headlamp with ballast. the ballast given data voltage 10-17v,current permenant 6amp, run up phase is 15amp, peak at swicth on max 400micro sec is 40amp.the sum of cable resistance is 150mohm.please provide referenc document if any for relating the peak at switch on current,time & wire wire size

2315


how could we calculate the no of outgoings from a 800 watt distribution board

1744


as a electrical student why should i hire you?

2437


What are conduct on the testing in cf in ur site?

1603


formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?

2148


How much depth n width required for laying of 1X70 Sqmm Cable in Desert???

1575


i need previous entrence exam papers of nhpc.

2783


hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.

2681