what is the difference between CT and CVT in EHV Sub Stations
Answer Posted / p krishna teja
A current transformer (CT) is used for measurement of
electric currents.Current transformers are commonly used in
metering and protective relays in the electrical power
industry.
A capacitor voltage transformer (CVT), or capacitance
coupled voltage transformer (CCVT) is a transformer used in
power systems to step down extra high voltage signals and
provide a low voltage signal, for measurement or to operate
a protective relay. In its most basic form the device
consists of three parts: two capacitors across which the
transmission line signal is split, an inductive element to
tune the device to the line frequency, and a transformer to
isolate and further step down the voltage for the
instrumentation or protective relay.
| Is This Answer Correct ? | 42 Yes | 2 No |
Post New Answer View All Answers
Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC
Is there any guideline say about display of earthing value near to earth pit
why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?
at work i have a genertor/alternater what is the easyest way to work out if it is dc or ac?
This is urgent!! What is a Thyristor-based 3-ways selector switch with Zero crossing control? how does it operate and where is it mostly found in a system?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
what is fault level of power system ?
How can maintain our H.T. motors used in cement plant. please send me procedure.
how to measure dc earth leakage current?
what types of electrical & mechanical test conducted in switchyard?
if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain
In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because
Why it is necessary to isolate fire fighting when you are taking shutdown for lv board.
How 3 phase invertor works?
what parameters are should nessary for control technic dc drive(in rolling mills)?