I am pujita completed Electronics and Instrumentation
Engineering.As a fresher i am going to attend the
interviews.Could anybody guide the topics/questions covered
mostly in interviews.
Answer Posted / arun kumar
the basic principle for Instrumentation engieners
1. what is instrumentation ?
2.what is the application
3.what are the instrumentation parameters to be measured in industries
4.where the instrumentation is more needed ?
5.what is flow ,temp,viscosity,prressure?
6.what is accuracy ,precision ,repeatability,resolution?
this are the basic questions to be faced in interview
this are only for instrumentation Engineeers
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
what is the importance of CV in the control valves? how it is calculated?
What is difference between ESD and PLC please Explain me clearly.
Please can anybody help for control valve sizing step by step procedure?
Why grounding is necessary? Give example with diagram.
1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.
for oil & gas industries which zone is normally preferred? why? give its example?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Why mixer nd grinder Is example of constant torque load not variable torque load ???
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?
what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.
how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
sir ,iam in dem urgent need of HPCL Paper of Instrumentation Branch plz send me at your earliest convenience at ujjwal_sharma1983@yahoo.com