is earthing is necessary if we use armoured
cable

Answer Posted / manikumar agcet

Earthing is not required if we
connect all armour strands of
the cable to ground.

Is This Answer Correct ?    10 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is creepage distance..... what will be the value for different voltage level

1506


what is the clear formula to calculate cable size for a load

1478


I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???

2136


a simple c++ program to calculate simple interst with its data members as private

1389


why transmission is only 3 phase and not 2 or 4 or poly phases

1706






If I want to buy a new Xformer for my plant what are the main parameter will I need to check?

1439


What is the formula to find out two phase active & reactive power

1697


How many kinds of E.L.C.B and how to work E.L.C.B

1601


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1679


what is the use of expulsition protective gap in 11Kv line.

1684


I need bhel electrical test pattern & paper

1397


I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)

1669


Why reactors use before incoming of ac vvfd drive?

1370


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

1482


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

1716