Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the purpose of Buffer in any titration?Ex:In
determination of hardness of water we use ammonia
ammoniachloride buffer in titration with EDTA.Why?

Answer Posted / suresh

Buffer is a substance it will little resist change in the
pH of the solution.

In Hardness estimation the major substances in water is
Calcium carbonate and magnesium carbonate. The ammonia and
ammonium chloride buffer pH is 10. At the particular pH it
will form the complex with both calcium and magnesium.So
the titre value gives the total hardness of the solution.
If you want to measure calcium alone instead of adding pH
10 buffer add pH 12 buffer (1M NaoH).

Is This Answer Correct ?    81 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to establish relative response factor for hplc. Why it is required?

1266


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

807


what type of question will ask in the interview of lab chemist.

3362


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2685


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

2328


what is biorelivent dissolution media?

859


cefoperozone and sulbactam inj. hplc test method

2742


what is partion and column chromatography

2466


why we use glass fiber filters use in some situation?

848


if identification threshold crosses the limits then what next step?

915


if instrument calibration fails then what require to do?

1017


how to select short coloum and long coloumn for new molecule

2522


How can I develope method of dissolution by HPLC OR UV

2455


What is shaking level in GC?

833


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3578